Skip to product information
1 of 11

Aurora Generators

Aurora Generators 28kW Perkins Diesel Generator/Open Enclosure - PowerGen USA - AGi28P-O

Aurora Generators 28kW Perkins Diesel Generator/Open Enclosure - PowerGen USA - AGi28P-O

1 Review

Only 9999 left!

Regular price $16,065.00
Regular price Sale price $16,065.00
Sale Sold out
Shipping calculated at checkout.
Style
View full details

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Aurora Generators 28kW Perkins Diesel Generator/Open Enclosure - PowerGen USA - AGi28P-O

THIS SIZE GENERATOR IS PERFECT FOR larger homes. Most homes are supplied with 200 Amp electrical service from the utility company. This generator can provide the same, so you can carry on using everything as if no power outage ever occurred.

JUST TAKE A LOOK AT WHAT YOU GET:

Long Runtime Diesel-powered engines can work hard 24/7 for extended periods - up to 3 weeks if necessary - and still outlast any other type of engine for a fraction of the operating costs. 

Reliability 

There's a reason the farming, transportation and construction industries have been leveraging the benefits offered by diesel generators for years.

Home Friendly 

New stringent emission regulations have produced clean diesel engine options that fit perfectly for home power generation. These strong, reliable long-life diesel engines have become today's preferred choice for home backup power. 

Clean and Safe 

Diesel fuel is a cleaner fuel that can be safely stored for long periods.

Quieter Running 

The higher the RPM, the louder the noise. Our diesel generators run in the 1800 RPM range, unlike non-diesel products that run at 3600.

Low Maintenance 

You only need to change the oil and filter every 500 hours instead of every 100 hours for a non-diesel generator.

Cost-Effective 

Diesel fuel is the least expensive to run, with natural gas and propane costing much more.

Flexible Warranty 

Diesel-powered generators seldom have any restrictions on use and can be used non-stop if needed. The warranty for natural gas, propane and gasoline-powered generators usually only covers emergency standby use.

ENGINE

• Perkins Diesel Engine Model 404D-22TG

• Four-cylinder

• Turbo Diesel

• 1800 RPM

• 2.2 Litre

ALTERNATOR

• Meccalte Model NPE32

• Brushless & maintenance-free

• Automatic Voltage Regulated

Output
• 60 Hz | 120/240 Volts
• 200 Amps @ 120 Volts
• 100 Amps @ 240 Vot
• Also Available in 3 Phase 120/208 & 277/480 Volts

INSTRUMENTATION & CONTROL

• DYNAGEN TG350 

• Auto-start & two-wire remote start compatible

• Displays voltage, speed, frequency, battery, fuel level, oil pressure, coolant temp, and more. 

• 150 Event Log

• Easy to use

• User re-programmable

• Password Protected 

FUEL TANK

• Built-in 12 gallon

• Electronic Fuel Level Sensor

• Mechanical Fuel Level Sensor

•Vented Fuel Fill / Cap

CONSTRUCTION

• All stainless steel fasteners used. 

• Powder-coated steel enclosure

• Powder-coated steel frame

• Vibration Mounts on engine and alternator

• Dimensions -  60" x 40" x 46" (L x W x H)

• Weight - 1,450 lbs

OTHER

• Includes Battery

MANUALS

• Generator Specifications
• Generator CAD Drawing
• Engine Specifications
• Engine Manual
• Controller Manual
• Alternator Manual

ACCESSORIES

• Oil Pan Heater
• Battery Charger
• Remote Monitoring & Control

GUIDES

• What size generator do I need?
• Wattage Guide (pdf)
• Blog
• See photos of customer installations
• Starting in cold weather

What Our Experts Think
  • High-Powered 28kW Output: The Aurora AGi28P-O Diesel Generator provides a robust 28kW of power, making it ideal for larger industrial applications, backup power for commercial operations, and off-grid locations.

  • Reliable Perkins Diesel Engine: Equipped with a Perkins diesel engine, this generator offers excellent fuel efficiency, reliability, and long-lasting performance while minimizing operating costs and maintenance.

  • Open Enclosure for Accessibility: The open-frame design of the AGi28P-O allows for easy access to components, better ventilation, and simplified maintenance, ensuring that you can customize the setup and service the generator with ease.

  • Heavy-Duty Construction: Built to withstand harsh environments, the AGi28P-O features durable, industrial-grade components designed for continuous, reliable operation even under demanding conditions.

  • Fuel-Efficient & Extended Runtime: Diesel engines are known for their long runtimes and superior fuel efficiency, ensuring lower fuel consumption and longer operational life compared to gasoline-powered generators.

  • Versatile & Cost-Effective: Ideal for a variety of applications including backup power, remote job sites, commercial facilities, and agricultural operations where high-powered, reliable energy is needed.

  • Made in the USA: Manufactured by PowerGen USA, ensuring top-tier craftsmanship and stringent quality control for long-lasting durability and performance.

Q&A

Q: What is the Aurora Generators 28 kW Perkins Diesel Generator - Open Enclosure?
A: The AGi28P-O is a 28 kW diesel generator powered by a Perkins engine, designed for reliable, continuous, or backup power. Its open-frame design provides easy access for maintenance and customization.

Q: What are the advantages of the open enclosure design?
A: The open-frame design offers better airflow, easier servicing, and flexible installation options while reducing overall costs compared to fully enclosed models.

Q: Is this generator suitable for both residential and commercial use?
A: Yes, it is ideal for both residential backup power and larger commercial or industrial applications, providing dependable power during outages or in off-grid locations.

Q: How efficient is the Perkins diesel engine?
A: Perkins engines are highly fuel-efficient, durable, and require minimal maintenance, offering a long-lasting, cost-effective power solution.

Q: Does this generator include an automatic transfer switch (ATS)?
A: No, an ATS is not included, but it can be added separately for seamless power transfer during outages.

Q: Where is this generator manufactured?
A: It is built in the USA by PowerGen USA, ensuring high-quality construction and reliability.

Maintenance Tips
  • Oil & Filter Changes – Change oil and filters every 100–250 hours to ensure smooth engine operation.
  • Fuel System Care – Use clean diesel, drain water separators, and replace fuel filters regularly to prevent clogging.
  • Battery Maintenance – Keep terminals clean and fully charged for reliable starting power.
  • Cooling System Check – Monitor coolant levels, inspect for leaks, and clean the radiator to avoid overheating.
  • Air Filter Maintenance – Clean or replace air filters regularly to ensure proper airflow and engine efficiency.
  • Exercise the Generator – Run under load monthly to keep the system lubricated and prevent fuel degradation.
  • Inspect Belts & Hoses – Check for wear, cracks, or leaks and replace any damaged parts.
  • Monitor Exhaust & Ventilation – Ensure proper airflow and check for unusual smoke or odors that may signal issues.
  • Electrical System Check – Inspect wiring, connections, and control systems to ensure safe operation.
  • Schedule Professional Servicing – Annual maintenance by a technician ensures the generator’s reliability and longevity.