Skip to product information
1 of 11

Proactive Medical

Proactive Medical Protekt Aire 6500 Mattress For Bariatric Low Air Loss/Alternating Pressure Mattress System

Proactive Medical Protekt Aire 6500 Mattress For Bariatric Low Air Loss/Alternating Pressure Mattress System

1 Review
5% Sale

Only 9999 left!

Regular price $494.99
Regular price $520.00 Sale price $494.99
Sale Sold out
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

Offer Price

$300.00

$100.00

Recently Viewed

Proactive Medical Protekt Aire 6500 Mattress For Bariatric Low Air Loss/Alternating Pressure Mattress System

Experience the ultimate in pressure ulcer treatment with the ProtektAire 6500 Bariatric Low Air Loss/Alternating Pressure Mattress from Proactive Medical. This advanced mattress is specifically designed for patients in stages 1-4, effectively utilizing both alternating pressure and low air loss therapies to optimize patient comfort and health outcomes. Equipped with 20 air bladders and a 10-minute cycle, it evenly distributes pressure across the mattress surface, providing maximum relief and promoting healing.

Proactive Medical Protekt Aire 6500 Mattress For Bariatric Low Air Loss/Alternating Pressure Mattress System

One of the standout features of the ProtektAire 6500 is its dual compressor with an impressive rate of 18 LPM (liters per minute). This ensures efficient air circulation, crucial for maintaining the mattress's therapeutic benefits. The alternating pressure cycles can be set at intervals of 10, 15, 20, or 25 minutes, allowing clinicians to customize pressure redistribution and skin surface interface tailored to each patient's needs. Plus, the cell-on-cell mattress design is a safety measure that prevents the patient from bottoming out in case of power failure, always ensuring patient support and comfort.

This mattress not only excels in pressure relief but also in managing moisture and temperature. The low air loss function controls and manages moisture to prevent skin maceration, an essential feature for patients at risk of pressure ulcers. The small laser holes on the mattress surface help keep users cool and dry, providing a comfortable resting environment. For clinicians' convenience, the mattress includes three audio/visual alarms—alerting to low pressure, power failure, and alternating failure—ensuring prompt and responsive care.

The ProtektAire 6500 also includes a seat inflate feature that increases air flow by 20% to the middle bladders, significantly reducing the risk of bottoming out during positioning or seating transitions. Additionally, the static mode facilitates easy and safe patient transfer in and out of bed. Another thoughtful feature is the pillow top design, which prevents undue movement of the head and neck during the alternating mode, enhancing overall comfort.

The mattress is constructed with a Nylon/PU material for the 10” air cells, providing added comfort and durability. The quilted top cover is fluid-resistant, anti-microbial, anti-bacterial, vapor permeable, and fire retardant, ensuring a hygienic and safe environment for patients. For quick emergency response, a CPR pull tab is included to rapidly release air from the mattress.

Robust and reliable, the Protekt Aire 6500 has a weight capacity of 750 lbs, making it suitable for bariatric patients. It also offers a 2-year non-prorated warranty, providing peace of mind and assured quality. Buy now at Mobility Ready to invest in the best care solution for patients with pressure ulcer risks.

Features 
  • Dual compressor with 18 LPM (liter per minute).
  • Alternating pressure cycles of 10, 15, 20 & 25 minutes allows clinicians to customize pressure redistribution and skin surface interface.
  • Cell-on-cell mattress design prevents patient from bottoming out in case of power failure.
  • 10” air cells are constructed of Nylon/PU for added comfort and support.
  • Low air loss function controls and manages moisture to prevent skin maceration.
  • 3 Audio/visual alarms; low pressure, power failure, and alternating failure alerts clinicians when preset pressure levels decrease.
  • Seat inflate increases air flow by 20% to middle bladders to prevent bottoming out.
  • Static mode allows for easy transfer in and out of bed.
  • Pillow top feature prevents head and neck from unnecessary movement during alternating mode.
  • Lock out feature prevents unauthorized changes to the pump settings.
  • Nylon quilted top cover is fluid resistant, anti-microbial/anti-bacterial, vapor permeable and fire retardant.
  • CPR pull tab quickly releases air from mattress.
  • Weight Capacity: 750 lbs.
Warranty
  • 2 Year Non-Prorated.

Order the Proactive Medical Protekt Aire 6500 Mattress For Bariatric Low Air Loss/Alternating Pressure Mattress System today from Mobility Ready. We provide free shipping across all our brands of Mattresses, and we guarantee the lowest prices while ensuring your satisfaction with hassle-free returns and secure shopping. Being authorized dealers, we assure you that you are getting a genuine product coupled with excellent customer service.

What Our Experts Think
  • Bariatric & Low Air Loss: Designed to support higher weight capacities safely.

  • Alternating Pressure System: Reduces pressure points and improves patient comfort.

  • Enhanced Airflow: Promotes skin health and prevents bedsores.

  • Durable Medical-Grade Construction: Long-lasting and easy to clean.

Q&A

Q: Who is this mattress designed for?
A: Ideal for bariatric patients or anyone requiring pressure relief during extended bed rest.

Q: How does the alternating pressure work?
A: The system cycles air between compartments to reduce pressure on vulnerable areas.

Q: Is it easy to maintain?
A: Yes, the medical-grade cover is wipeable and designed for routine cleaning.

Maintenance Tips
  • Check air pump and hoses regularly for leaks.

  • Clean mattress surface with approved disinfectants.

  • Inspect cells and seams periodically for wear.

  • Follow manufacturer’s guidelines for air pressure settings.